Monoblock industrial burners are commonly known as burners, and there are many types and specifications, including oil, gas (gas), and coal (pulverized coal/coal water slurry). The application field is very wide, and the burner is needed in the industrial occasions that need to burn the fuel to heat the material or react.
operating
1. For the newly installed furnace body, carefully check whether the gas meets the requirements of the burner before commissioning; check whether the detection instrument on the gas supply pipeline is normal and whether the pipeline valve is opened and closed properly, and whether it is convenient for future use and maintenance.
2. For newly installed pipelines, carefully check the installation reliability of all pipelines and the tightness of the pipelines.
3. Users who use a separate gasification station must ensure that the gas supply volume and gas supply parameters meet the requirements for safe combustion.
4. The operator carefully reads the equipment manual, and is proficient in the knowledge and methods of safe operation.
5. Check whether the gas valve is open every time before starting up, otherwise the burner will not work.
6. Start the power control button on the control cabinet, and the digital display will display the current temperature in the furnace at this time. The temperature of the newly installed furnace body is the ambient temperature.
7. Start the fan control button and the fan installed on the furnace body will work. At this time, if the fan is damaged, the control cabinet will be automatically protected from entering the next operation.
8. When the combustion-supporting fan works without abnormal phenomena, restart the combustion control button, and the combustion program controller starts to work at this time. It performs ignition, air supply, flame detection, and other programs through a certain program to finally achieve safe combustion.
9. When the combustion controller receives a signal that is not conducive to combustion (for example: ignition failure, unstable air pressure, circuit problems) and other problems, the combustion controller immediately shuts off the gas and sends out an alarm signal.
10. If the combustion controller alarms, it must be manually reset by the operator after the fault is resolved before it can continue to work.
11. For the operation of the entire equipment, the operator should refer to the furnace safety operating procedures and production process requirements.
12. When the control temperature needs to be adjusted according to the requirements of the production process, the operator should refer to the instructions of the intelligent numerical control table for adjustment.